QTOF Micro
- Brand: Micromass
- Product Code: QTOF Micro
- Availability: In Stock
Data Sheet: QTOF Micro Data Sheet.pdf
Refurbished Micromass/Waters Q-TOF Micro complete with ESI probe, PC, MassLynx 4.0 software, Edwards vacuum pump and Neslab Chiller. OPTIONAL: Nano Lock spray with controller (p/n 3889001DC3), Taurus ESI Probe Installation Kit & ESI Probe Assembly Spares Kit. The QTOF Micro is a bench-top, quadrupole time-of-flight hybrid mass spectrometer that can be configured for a wide range of LC-MS and LC-MS/MS applications.
Q TOF MICRO KEY FEATURES
Z-SPRAY ATMOSPHERIC PRESSURE IONIZATION SOURCE
The nebulized spray is orientated orthogonally and positioned off axis for maximum source longevity and analyzer protection against "dirty" samples, including Electrospray Probe allowing flow rate of 1-1000 ut/min directly into source.
QUADRUPOLE ANALYSER
Precision engineered quadrupole analyzer mounted in a ceramic cradle. The standard mass range is 40 m/z to 4000 m/z resolving mode and 45 m/z to 20,000 m/z RF only mode.
COLLISION CELL
High efficiency, 160mm hexapole collision cell. Collision energy is digitally controlled in the range 0 to +/- 200 V. Collision gas introduction and removal from the cell are also under software control.
ORTHOGONAL ACCELERATION TIME OF FLIGHT ANALYZER
Precision engineered orthogonal acceleration time-of-flight mass spectrometer for MS and MS/MS data acquisition, comprising ion injection cell, high precision reflectron, chevron microchannel plate and time to digital convertor (TDC) ion counting system operating at up to 3.6 GHz. Please contact us for complete used and refurbished Micromass QTOF micro /Waters Q-TOF micro system, warranty and service contract details.
Q TOF MICRO KEY FEATURES
Z-SPRAY ATMOSPHERIC PRESSURE IONIZATION SOURCE
The nebulized spray is orientated orthogonally and positioned off axis for maximum source longevity and analyzer protection against "dirty" samples, including Electrospray Probe allowing flow rate of 1-1000 ut/min directly into source.
QUADRUPOLE ANALYSER
Precision engineered quadrupole analyzer mounted in a ceramic cradle. The standard mass range is 40 m/z to 4000 m/z resolving mode and 45 m/z to 20,000 m/z RF only mode.
COLLISION CELL
High efficiency, 160mm hexapole collision cell. Collision energy is digitally controlled in the range 0 to +/- 200 V. Collision gas introduction and removal from the cell are also under software control.
ORTHOGONAL ACCELERATION TIME OF FLIGHT ANALYZER
Precision engineered orthogonal acceleration time-of-flight mass spectrometer for MS and MS/MS data acquisition, comprising ion injection cell, high precision reflectron, chevron microchannel plate and time to digital convertor (TDC) ion counting system operating at up to 3.6 GHz. Please contact us for complete used and refurbished Micromass QTOF micro /Waters Q-TOF micro system, warranty and service contract details.